TMS Chapter A: Event Codes
156
211 Warning Switch <ShoreGear Switch
Host Name> booted via FTP.
Possible switch firmware
corruption. A failure
experienced during firmware
upgrade will leave a switch
booting via FTP instead of
from its firmware.
The switch is no longer able
to boot from flash memory
and is now booting via FTP.
The cause of the error is a
failed firmware upgrade, bad
firmware, or a reset caused by
pressing the reset button.
Reburn flash memory.
On the ShoreWare server, open a command
prompt window and change the directory to
the ShoreWare server directory (typical
path is Program Files\Shoreline
Teleworks\ShoreWare Server).
Enter the burnflash command in this
format:
burnflash -s <IP address>
(Use the IP address of the switch you are
upgrading.)
When the burnflash process is complete,
check the event logs to confirm that the
switch is no longer booting from FTP.
If the event persists, replace the switch.
212 Warning Switch <ShoreGear Switch
Host Name> software version
mismatch: TMS Version:
<TMS version> Switch
Ve rs i on : <ShoreGear Switch
version> The switch firmware
will be upgraded the next time
the switch boots.
TMS detects a switch with
outdated firmware.
New switches ship with base firmware that
is “down” from the current version. An
automatic upgrade is confirmed when the
device is put into service.
(This event also appears during field
upgrades.)
From ShoreWare Director, open the Quick
Look page and reboot the switch.
213 Error Unexpected Ethernet address
for switch <ShoreGear Switch
Host Name> Expect:<MAC
Address> Found:<MAC
Address>. The switch is
reporting an Ethernet address
different from the one
specified in the configuration
database.
The MAC address in the
switch’s configuration record
is incorrect.
From ShoreWare Director, open the switch
configuration record and correct the MAC
address.
214 Warning Switch “<ShoreGear Switch
Host Name>” firmware file
version mismatch: TMS
Ve r s i o n: < TMS Version> File
Ve r s i o n: < File version>
Cannot upgrade switch
firmware. The firmware file
used to upgrade the switch
firmware does not have the
correct version.
The firmware file filessys.dll
does not match the TMS file
version.
The switch’s firmware cannot
be upgraded.
Re-install the ShoreWare server software.
If the event persists, contact ShoreTel
Customer Support.
221 Error Failed to load firmware image
file <FileSys.dll>. The
Telephony Management
Server was unable to load the
switch firmware image file.
A switch firmware upgrade
may not be possible.
This error appears when the “\Shoreline
Communications\ShoreWare Server” does
not have the “FileSys.dll” file, and TMS
can’t find or access this file.
If this error appears frequently, contact
ShoreTel Customer Support.